SHEDAR Global Materials
Home/News/Hot-Dip Galvanizing or Paint for Structural Steel? How to Specify the Finish
Quality & Standards•NOVEMBER 11, 2026

Hot-Dip Galvanizing or Paint for Structural Steel? How to Specify the Finish

Specify the finish by naming the coating standard: typically hot-dip galvanizing to ASTM A123/A123M or EN ISO 1461, a paint system, or a duplex system. Confirmed per order and per drawing.

Hot-Dip Galvanizing or Paint for Structural Steel? How to Specify the Finish

Short answer

For structural steel, specify the finish by naming the coating standard and system the project requires — typically hot-dip galvanizing to ASTM A123/A123M or EN ISO 1461, a paint system with the stated surface preparation, or a duplex system (galvanizing plus a subsequent paint or powder coating). These options are not interchangeable without the project engineer's agreement. Batch hot-dip galvanizing of sections, plates, bars and fabricated steel is not the same process as continuous galvanizing of steel sheet. SHEDAR supplies structural steel sourced to order through our established supply channel in China. Grade, section, testing and finish are confirmed per order and per drawing.

What the main galvanizing standards cover

  • ASTM A123/A123M is the standard specification for zinc (hot-dip galvanized) coatings on iron and steel products made from rolled, pressed and forged shapes, castings, plates, bars and strips. It covers both unfabricated products and fabricated products, including structural steel fabrications.
  • It does not apply to wire, pipe, tube or steel sheet that is galvanized on specialized or continuous lines. Hardware items that are centrifuged to remove excess zinc, such as bolts and similar fasteners, are specified to ASTM A153/A153M rather than A123.
  • EN ISO 1461 specifies the general properties and test methods for hot-dip galvanized coatings applied by dipping fabricated iron and steel articles in a zinc melt. It likewise does not apply to continuously galvanized sheet, wire or mesh, to tube and pipe galvanized in automatic plants, or to products such as fasteners that have their own coating standards. It also does not cover after-treatment or additional coating of galvanized articles.

State the standard (and the edition if the drawing names one) on the RFQ. Do not assume that a galvanized sheet or coil specification covers a galvanized beam or fabricated frame.

Paint and duplex systems

A paint system is defined by the project specification, including surface preparation, the paint products and the inspection criteria. A colour code alone does not define the coating system.

A duplex system is a hot-dip galvanized coating plus a subsequent paint or powder coating. Because EN ISO 1461 does not cover after-treatment or additional coatings, the paint or powder system has to be specified in addition to the galvanizing standard. Suitability of any duplex or paint system is confirmed per the project specification.

How to specify the finish in an RFQ

  1. State whether the steel is to be supplied bare (as-rolled), primed, hot-dip galvanized, painted, or duplex-coated.
  2. Name the coating standard and any edition given on the drawing (for example ASTM A123/A123M or EN ISO 1461).
  3. For paint or duplex systems, attach the project coating specification and any required colour, gloss or texture reference. Confirm a physical sample where appearance matters; a screen image is not a production colour approval.
  4. Say whether fabrication (cutting, drilling, welding) will be completed before galvanizing. Field cuts and welds need a repair method named by the project specification.
  5. List any coating inspection or test documents the order requires. MTC can be provided per order.

SHEDAR supplies structural steel sourced to order through our established supply channel in China. Grade, section and testing are confirmed per order and per drawing.

FAQ

Is hot-dip galvanizing the same as galvanized steel sheet or PPGI?

No. ASTM A123/A123M and EN ISO 1461 cover batch hot-dip galvanizing of products such as shapes, plates, bars and fabricated steel. Continuously galvanized sheet, wire and tube are covered by other standards. PPGI is colour-coated steel sheet and is a different product.

Should I specify ASTM A123 or EN ISO 1461?

Use the standard named on the project drawing. They both address hot-dip galvanized coatings on fabricated iron and steel, but they are different documents. Do not treat them as a drop-in substitute without the engineer's agreement.

Do bolts and other fasteners follow the same galvanizing standard as the beams?

Usually not. ASTM A123/A123M directs hardware that is centrifuged to remove excess zinc, such as bolts and similar fasteners, to ASTM A153/A153M. EN ISO 1461 also excludes products that have their own coating standards, including fasteners.

Is a paint colour code enough to specify a coating?

No. State the substrate, the surface preparation, the paint or duplex system, and the project inspection requirements. Colour, gloss and texture should be confirmed with a physical sample where appearance matters.

Can you supply steel to a finish standard not listed here?

Send the standard, the grade, the section and the drawing. Grade, section, testing and finish are confirmed per order.

Need H Beam or Other Structural Steel?

Tell us the grade, size, quantity, and destination port. We will reply as soon as possible.

WhatsApp: +86 187 6618 5630